• SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

After-sales Service: 24-hour online service,free accessories
Warranty: 2 Years
Display: computer
Appliance: Food Analysis, Medical Research, Biochemistry
Portable: Benchtop
Certification: CE, ISO9001
Samples:
US$ 17600/unit 1 unit(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Shandong, China
Importers and Exporters
The supplier has import and export rights
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (21)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
TOC-A5000
Type
TOC Analyzer
Detection Range
0-50000mg/L
Method
High temperature combustion
Parameters
TC,TIC,TOC,NPOC
Detector
NDIR
Transport Package
Standard Export Package
Specification
0-50000mg/L
Trademark
SCITEK
Origin
China

Product Description

Product Description
SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
  • High-performance processing power guarantees steady and dependable system operation.

  • Modular design makes gadget maintenance and operation simpler.

  • NDIR detector that was imported, ensuring greater sensitivity and stability.

  • PID temperature control technique, which achieves greater precision.

  • Precise gas flow control technologies increase accuracy.

  • An innovative three-stage dehydration process increases drying effectiveness.

  • Dilution, acid addition, and purging of samples automatically.

  • A special liquid path and flow control system extends the service life of the catalyst.

  • Monitoring of diluted water and wastewater in real-time.

  • Multipurpose computer software

  • Users greatly benefit from personalized standard curve management because it is so convenient.

  • Users are reminded to change consumables on time by consumables management.

  • The optional 20-position autosampler saves 80% of the time and energy

 

Product Parameters
 
Model TOC-A5000
Detector NDIR
Method High temperature combustion
Parameters TC,TIC,TOC,NPOC
Operation Mode PC software controlled
Application Liquid sample
Gas Requirement Oxygen >99.995%
Measurement Range 0-50000mg/L
Electricity AC 220V, 50/60Hz ;110V, 50/60Hz
Size(W×D×H)(mm) 500x450x480
Shipping size(W×D×H)(mm) 780x710x610(Main device);
550x260x550(Accessories)
N.W./G.W. (kg) 46kg(Main device)+4kg(Accessories)
/70kg(Main device)+8kg(Accessories)
Software introduction
Standard Curve All detailed sample and measurement info would be displayed clearly.
Automatically append measurements to meet RSD or SD limits.
Real-time display of peak shape, easy to make comparisons.
Sample Measurement Quick setting of measurement mode and ID info.
Real-time monitoring of temperature and airflow, an alarm is initiated when exception occurs.
Real-time display of measurement data and peak shape.
Consumables Management Available to set and check the service life and service condition of consumables.
Timely reminding users to replace consumables.
Measurement Record

Easy to retrieve sample info, measurement data and peak shape.

Measurement report can be exported in Excel or PDF format.

Test report under Single-sample or Multi-sample mode can be selected flexibly to meet 

different requirements.

Software introduction
Multi-channel rotary valve system Quantitative pump ensures precision injection volume.
Single-point dilution, quick and convenient.
Wide sample measurement range, max. autoatic dilution ratio 100.
High temperature pyrolysis module Pyrolysis temperature can be set as required.
Precision temperature control system, the highest temperature 1000°C.
IC Reaction Module Complete IC digestion by acid-adding and heating.
Electronic cooling system, filter and membrane dryer effectively remove water vapor
NDIR Detector Imported light source, detector and special gas chamber.
Stable results, lower noise, wider detection range and faster speed.
A constant temperature environment ensures high stability and accuracy.
Company Profile

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer
Certifications

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

Our Advantages

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

Packaging & Shipping

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

FAQ

SCITEK Total Organic Carbon Analyzer High temperature combustion TOC AnalyzerSCITEK Total Organic Carbon Analyzer High temperature combustion TOC Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Plant Area
1291 square meters
Management System Certification
ISO9001:2015, ISO14001:2015