Unique to this device is its direct concentration display, which instantly shows the concentration results from the analysis without tedious calculations. The automatic computation of correlation coefficients greatly simplifies the complexity of data analysis, providing users with more efficient and accurate results.
In addition, the photometer provides a pre-selected flame size function, allowing the user to adjust the flame size according to the experiment's needs, and is equipped with a flame extinguishing protection device to ensure the stability and safety of the experiment.
The measurement range can be flexibly adjusted as required, allowing the user to cover different concentration ranges, and this flexibility is essential for users in other application areas. In addition, the user can select different concentration units, making them more suitable for different experiments or industry standards.
Model | SP-FP6450 | SP-FP6440 | SP-FP6431 | SP-FP6430 | SP-FP6410 | SP-FP640 | |
Operation Mode | 7- inch color touch- screen | ||||||
Display Value | Concentration value | Optical power | |||||
Data Range | 0.000~999.9 | 000.0~999.9 | 0000~9999 | ||||
Testable | K, Na, Li, Ca, Ba | K, Na, Li, Ca | K, Na, Ca | K, Na, Li | K, Na | K, Na | |
Channel Qty. | 5 | 4 | 3 | 2 | |||
Range ppm | K | 0-100 | |||||
Na | 0-160 | ||||||
Li | 0-100 | O | 0-100 | O | O | ||
Ca | 0-1000 | 0-1000 | O | O | O | ||
Ba | 0-3000 | O | O | O | O | O | |
LOD ppm | K | 0.01 | |||||
Na | 0.01 | ||||||
Li | 0.1 | O | 0.1 | O | O | ||
Ca | 2 | 2 | O | O | O | ||
Ba | 6 | O | O | O | O | O | |
Linear Error | K | 0.195 | |||||
Na | 0.69 | ||||||
Li | 0.15 | O | 0.15 | O | O | ||
Ca | 3 | 3 | O | O | O | ||
Ba | 9 | O | O | O | O | O | |
Response Time | <8s | ||||||
Sample Uptake | <6ml/min | ||||||
Stability | < 3% drift over15s when continuously aspirating. | ||||||
Reproducibility | < 3% coefficient of variation for 7 consecutive samples | ||||||
Curve Graph | Display | O | O | ||||
Printer | Optional build-in thermal printer | O | |||||
COM | USB | O | |||||
Fuel | LPG | ||||||
Power | AC220V±22V; 50Hz±1Hz, 250W | ||||||
Sizes (W×D×H)(mm) | 470×460×300 | ||||||
Shipping Size (W×D×H)(mm) | 570×560×400 | ||||||
N.W./G.W. (kg) | 15/20 |