Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | PCR Analyzer |
Still deciding? Get samples of US$ 3000/unit
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PCR-IAF16 is an economical dual-channel isothermal amplification fluorescence PCR detection system that is compact and lightweight. It is suitable for rapidly detecting viruses, mycoplasmas, fungi and other microorganisms. It is very popular in disease prevention and control, agriculture and forestry.
The sidelight detection system can detect a minimum of 20 ul reaction volume, saving experimental materials and reagents and improving detection accuracy.
The accuracy of temperature control is up to 0.1°C. The fluorescence signal is monitored in real-time to avoid subjective errors caused by manual interpretation.
Negative and positive results are directly displayed without any other calculation.
7-inch touch screen, setup, detection, interpretation, saving and other independent operations, without any operation
It can connect to a computer, using USB to transfer the experimental data and results to the computer, and can also be connected to the printing device to print the test results directly
Small size, rechargeable battery, anytime, anywhere, real-time testing
Support real-time data transmission, real-time monitoring system, automatic identification of negative and positive, melting curve and other functions.
Model | PCR-IAF16 | PCR-IAF16I | |
Sample Tray | Sample Size | 0.2mL-16 holes (8-strip tubes are available) | |
Reaction System | 15-150μL (recommended 25-30μL) | ||
Applicable Dyes | FAM/ROX etc. | ||
Temperature Control | Temperature Range (ºC) | RT~99ºC | |
Maximum Heating Rate (ºC) | 2ºC/s | ||
Maximum Cooling Rate (ºC) | 2ºC/s | ||
Temperature Uniformity (ºC) | ±0.15ºC | ||
Temperature Accuracy/Temperature Control Accuracy (ºC) | ±0.1ºC/0.1ºC | ||
Hot Lid Function | Yes, the temperature is adjustable | ||
Light Path System | Channel | Single/dual channel optional | Dual channel |
Excitation Wavelength | 470nm/570nm | ||
Detection Wavelength | 525nm/625nm | ||
Excitation Light Source/Detection Method | Cold light source LED/real-time fluorescent signal detection | ||
Function | Data Analysis | According to the tested samples, direct analysis to determine positive or negative | |
Result Display Method | 1. Negative/positive | ||
2. Peak starting time | |||
3. Melting Tm value | |||
Interpretation Method | 1. Construction of the amplification curve to judge; | ||
2. Automatic judgment of the instrument | |||
Display Screen | 7-inch touch screen | ||
Controlling Software | Instrument software | ||
Power Supply | Power Supply | AC100-240V 50/60Hz,DC15V6A | |
Size and Weight | Size(W×D×H)(mm) | 195x275x112 | |
Shipping Size(W×D×H)(mm) | 520x440x340 | 520x440x340 | |
N.W./G.W. (kg) | 3.5/6.5 | 3.6/6.5 |