Model |
MWQ-B900 |
MWQ-B901 |
MWQ-B902 |
MWQ-B903 |
MWQ-B904 |
pH |
Range |
-2.000~20.000pH |
- |
Resolution |
0.001, 0.01, 0.1pH, selectable |
- |
Accuracy |
±0.002pH |
- |
Calibration Points |
1 to 5 points |
- |
pH Buffer Options |
USA, NIST, DIN, 2 custom buffers |
- |
ORP |
Range |
±1999.9mV |
- |
Resolution |
0.1, 1mV, selectable |
- |
Accuracy |
±0.2mV |
- |
Calibration Points |
1 point |
- |
1 point |
1 point |
- |
Ion |
Range |
0.001~19999 (depending on the range of ISE) |
- |
- |
- |
- |
Resolution |
0.001, 0.01, 0.1, 1 |
- |
- |
- |
- |
Accuracy |
±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
- |
- |
- |
- |
Measurement Units |
ppm, mg/L, mol/L, mmol/L |
- |
- |
- |
- |
Calibration Points |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
- |
- |
- |
- |
Conductivity |
Range |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
- |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution |
0.001,0.01,0.1,1 |
- |
0.001,0.01,0.1,1 |
Accuracy |
±0.5% F.S. |
- |
±0.5% F.S. |
Calibration Points |
1 to 5 points |
- |
1 to 5 points |
Calibration Solutions |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
- |
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
Temperature Coefficient |
Linear (0.0~10.0%/°C), pure water |
- |
Linear (0.0~10.0%/°C), pure water |
Reference Temperature |
20/25°c |
- |
20/25°c |
Cell Constant |
K=0.1, 1, 10 or custom |
- |
K=0.1, 1, 10 or custom |
TDS |
Range |
0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
- |
0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution |
0.01,0.1,1 |
- |
0.01,0.1,1 |
Accuracy |
±1% F.S. |
- |
±1% F.S. |
TDS Factor |
0.1~1.0 (default 0.5) |
- |
0.1~1.0 (default 0.5) |
Salinity |
Range |
0.00~42.00psu, 0.00~80.00ppt |
- |
0.00~42.00psu, 0.00~80.00ppt |
- |
0.00~42.00psu, 0.00~80.00ppt |
Resolution |
0.01 |
- |
0.01 |
- |
0.01 |
Accuracy |
±1% F.S. |
- |
±1% F.S. |
- |
±1% F.S. |
Resistivity |
Range |
0.00~20.00MΩ |
- |
0.00~20.00MΩ |
- |
0.00~20.00MΩ |
Resolution |
0.01 |
- |
0.01 |
- |
0.01 |
Accuracy |
±1% F.S. |
- |
±1% F.S. |
- |
±1% F.S. |
DO |
Range |
0.00~20.00mg/L, 0.0~200.0% saturation |
- |
- |
0.00~20.00mg/L, 0.0~200.0% saturation |
0.00~20.00mg/L, 0.0~200.0% saturation |
Resolution |
0.01mg/L, 0.1% |
- |
- |
0.01mg/L, 0.1% |
0.01mg/L, 0.1% |
Accuracy |
±0.2mg/L, ±2.0% |
- |
- |
±0.2mg/L, ±2.0% |
±0.2mg/L, ±2.0% |
Calibration Points |
1or 2 points |
- |
- |
1or 2 points |
1or 2 points |
Barometric Pressure Correction |
60.0~112.5kPa/ 450~850mmHg, manual |
- |
- |
60.0~112.5kPa/ 450~850mmHg, manual |
60.0~112.5kPa/ 450~850mmHg, manual |
Salinity Correction |
0.0~50.0g/L, manual |
- |
- |
0.0~50.0g/L, manual |
0.0~50.0g/L, manual |
General Spec. |
Temperature Compensation |
0~100°C/32~212°F, manual or automatic |
Memory |
500 data sets, USB communication interface |
Power Requirements |
DC5V power adapter |
Sizes(W×D×H) |
210×188x60 |
Shipping Size (W×D×H)(mm) |
300x250x200 |
N.W./G.W. (kg) |
1.5/2 |