Customization: | Available |
---|---|
After-sales Service: | 24-hour online service,free accessories |
Application: | Laboratory Apparatus |
Still deciding? Get samples of US$ 14990/unit
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Full titanium burner, stable combustion and fast heat balance.
Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Model | SP-AA3638 | SP-AA3668 | |
Optical System | Optical System | Single Beam | Double Beam |
Monochromator | Czerny-Turner type, focal lengths at 350mm | ||
Grating | Grating 1800 lines/mm, scintillation wavelength 250nm | ||
Spectral Bandwidth (nm) | 0.1, 0.2, 0.4, 0.7, 1.4, 2nm | ||
Automated slit selection | |||
Wavelength Range (nm) | 185-900nm | ||
Wavelength Accuracy (nm) | 0.20 nm | 0.15nm | |
Wavelength Repeatability (nm) | ≤0.10nm | ≤0.05nm | |
Spectral Bandwidth Deviation | ±0.02 nm | ||
Lamp Stand | 8 | ||
Element Lamp Type | Cu lamp, Cd lamp(Standard accessory) | ||
Other element lamp is optional accessory | |||
Photometric Performance | Reading Mode | Transmittance, absorbance, concentration | |
Photometric Range | 0-125%, -0.1-3.00A | ||
Static Baseline Drift (Cu) | ±0.003A/30min | ±0.003A/30min | |
Dynamic Baseline Drift (Cu) | ±0.005A/15min | ±0.005A/15min | |
Flame System | Characteristic Concentration (Cu) | ≤0.035ug/ml | ≤0.035ug/ml |
Detection Limit (Cu) | ≤0.006ug/ml | ≤0.004ug/ml | |
Repeatability (Cu) | RSD≤0.6% | RSD≤0.5% | |
Acetylene Flow Control | Auto 12-Level | ||
Air Assist Control | Auto 4-Level | ||
Burner Lift | Automatic lifting | ||
Burner Head | Titanium 100mm burner | ||
Nebulizer | High efficiency glass nebulizer | ||
Spray Chamber | Corrosion-resistant material spray chamber | ||
Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched | ||
Graphite Furnace | Characteristic Amount | Cd≤0.8pg,Cu≤20pg | Cd≤0.8pg,Cu≤20pg |
Detection Limit | Cd≤1.0pg,Cu≤10pg | Cd≤0.8pg,Cu≤5pg | |
Repeatability(Cd) | RSD≤3% | RSD≤2.5% | |
Heating Range of Graphite Furnace | Room temperature-3000ºC | ||
High Power Heating Range | 1500-3000ºC | ||
Slope and Holding Time | 1s-255s | ||
Heating Rate | Maximum heating rate 2000°C/s | ||
Atomization Heating Mode | Light-controlled heating, Time-controlled heating, General heating | ||
Protective Gas Flow Outside Pipe | 1 L/min | ||
Protective Gas Flow Inside Pipe | 4-speed adjustable (0, 50, 200, 250ml/min flow) | ||
Safety Protection | Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm | ||
Data Processing | Measuring Method | Measuring method | |
Concentration Calculation Method | Concentration calculation method | ||
Repeat Measurement Times | Repeat measurement times | ||
Report Printing | Report printing | ||
Other | Computer | External connect | |
Ambient Temp | 10ºC-30ºC | ||
Ambient Humidity | 40%-85% | ||
Power Supply | 220V, 50/60HZ | ||
External Size (WxDxH)(mm) | 830x650x560 | ||
Shipping Size (WxDxH)(mm) | 1000x780x810 | ||
N.W./G.W. (kg) | 110/130 | ||
Standard Accessory | Software, Cd Hollow cathode lamp, Pipette | ||
Optional Accessory | Computer, Printer, Autosampler, Recirculating cooling water system |