1. 7 inch high-definition capacitive touch screen can also detect no need to connect to the computer.
2. Detection wavelength range: 190-850nm
3. Basic measurement requires only a 0.5-2μL sample, even if high-concentration samples do not need to be diluted.
4. With OD600 optical path detection system and cuvette mode, it is convenient for bacteria, microorganisms and other culture fluid concentration detection.
5. Automatically detects the closure of the detection arm.
6. The detection speed is breakneck.
7. Sample without dilution
8. A Built-in printer can directly print the report.
9. xenon flash lamp life of up to 1 billion times (up to 10 years). You can use it directly without preheating.
10. Each sub-catalog can store 100,000 data.
11. Detection limit in fluorometer mode can be as low as 0.5 pg/μL (for SP-MUV1000F only).
Model | SP-MUV1000 | SP-MUV1000I | |
Wavelength Range | 190-850nm | 190-850nm | |
Sample Capacity | 0.5-2μl | 0.5-2μl | |
Optical Distance | 0.05mmx0.2mm, 1.0mm (automatic switchover) | 0.05mmx0.2mm, 1.0mm | |
(automatic switchover ) | |||
Light Source/Life | Xenon lamp/109 times | Xenon lamp/109 times | |
Detector | 2048 element linear CCD array | 2048 element linear CCD array | |
Spectral Bandwidth | 2nm | 2nm | |
Absorbed Light Accuracy | 0.003Abs | 0.003Abs | |
Absorbance Accuracy | ±1% (7.332Abs at 260nm) | ±1% (7.332Abs at 260nm) | |
Absorbance Range | (Equivalent to 10mm) 0.04-300A | (Equivalent to 10mm) 0.04-300A | |
Nucleic Acid Concentration Range | 2ng/μL dsDNA~ | 2ng/μL dsDNA~ | |
15000ng/μL | 15000ng/μL | ||
dsDNA | dsDNA | ||
Detection Time | ≤5 s | ≤5 s | |
OD600 | Absorbance Range | 0~4.000 Abs | 0~4.000 Abs |
Absorbance Stability | [0,3)≤0. 5%, | [0,3)≤0. 5%, | |
[3,4) ≤1% | [3,4) ≤1% | ||
Absorbance Repeatability | [0,3)≤0. 5%, | [0,3)≤0. 5%, | |
[3,4) ≤1% | [3,4) ≤1% | ||
Absorbance Accuracy | [0,3)< 0.005A+1%; [3, 4) ≤2% | [0,3)< 0.005A+1%; [3, 4) ≤2% | |
Fluorescence Detection | / | Excitation wavelength: 460nm | |
Emission wavelength: 525nm | |||
Fluorescence Detection | Linearity | / | R2>0.995 |
Repeatability | / | <1.5% | |
Stability | / | <1.5% | |
Built-in thermal printer | Built-in thermal printer | ||
Data Output Mode | USB | USB | |
Material of Sample Base | Quartz optical fiber and high hard aluminum | Quartz optical fiber and high hard aluminum | |
Input Voltage | VAC 100-240V; VDC 24V 2A | VAC 100-240V; VDC 24V 2A | |
Power | <15W (Standby: 5W) | <15W (Standby: 5W) | |
Size(W×D×H)(mm) | 290x208x180 | ||
Shipping Size(W×D×H)(mm) | 500x430x290 | ||
N.W./G.W. (kg) | 3.2/5 |