SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Product Details
Customization: Available
After-sales Service: 24-hour online service,free accessories
Application: Laboratory Apparatus
Still deciding? Get samples of US$ 14999/unit
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Overseas Services
The supplier provides overseas services and supports countries including According to customer demand.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (33)
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
  • SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Company Profile
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
SP-AA3668
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
185-900nm
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
CE, ISO 9001/14001/45001
Customized
Customized
Optical System
Double Beam
Wavelength Range (nm)
185-900nm
Monochromator
Czerny-Turner type, focal lengths at 350mm
Grating
Grating 1800 lines/mm
Wavelength Accuracy (nm)
0.15nm
Transport Package
Standard Export Package
Specification
SP-AA3668
Trademark
SCITEK
Origin
China
HS Code
9027300090
Production Capacity
100 Units/Months

Packaging & Delivery

Package Size
100.00cm * 78.00cm * 81.00cm
Package Gross Weight
130.000kg

Product Description

Product Description

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Atomic Absorption Spectrophotometer Features:

  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.

  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.

  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.

  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.

  5. Both the flame and graphite furnace systems have lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.

  6. Full titanium burner, stable combustion and fast heat balance.

  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.

  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.

  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.

The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

Product Parameters

Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000ºC
High Power Heating Range 1500-3000ºC
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10ºC-30ºC
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system

Certifications

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Company Profile

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Our Advantages

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Packaging & Shipping

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

FAQ

SCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis ElementsSCITEK Double Beam Atomic Absorption Spectrophotometer for Analysis Elements

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More