Customization: | Available |
---|---|
After-sales Service: | 24-hour online service,free accessories |
Warranty: | 18 month |
Still deciding? Get samples of US$ 4010/Unit
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
It is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation. Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve.
Seven temperature control devices, the temperature control accuracy is lower than ±0.1ºC
Double over-temperature protection and power-off protection function
Linkage trigger signal acquisition system
With fault self-check and alarm function
The inlet can be installed up to 4 types (packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.
The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling
Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies. The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.
Ethernet communication interface is adopted, so that the instrument can realize long-distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data
The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of background noise, which can lead to lower detection limits.
GC-900 gas chromatograph is a popular, high-performance, multi-functional series of chromatographic instruments. FID, TCD and FPD detectors can be combined as needed to meet the needs of ordinary laboratories, daily production, routine detection and trace quantities analysis requirements. It can be widely used in many fields such as petroleum, chemical industry, environment, food safety, disease control, teaching and scientific research.
Model | GC-900 | |
Oven | Temp. Range | RT+5~450ºC |
Temp. Accuracy | ≤±0.1ºC | |
Temp. Program | 20-phase | |
Max. Temp. Heating Rate | 40ºC/min | |
Time Range | 0-655min | |
Internal Size | 250x270x170mm | |
Detector | Hydrogen Flame Ionization Detector (FID) | Detection limit: ≤5×10-12g/s (100ng/ul n-hexadecane-isooctane solution) Temperature 450ºC Compatible with packed and capillary columns Baseline drift: ≤2x10-13A/30min Baseline noise: 3×10-14A Dynamic range: ≥107 |
Thermal Conductivity Detector (TCD) | Sensitivity: >5000mv.ml/mg (50mg/ml toluene-benzene solution) Temperature 400ºC Baseline drift: ≤0.1mV/30min Baseline noise: 0.03mV Dynamic range: ≥105 (±10%) |
|
Flame Photometric Detector (FPD) | Detection limit: ≤5×10-12g/s (S of 10ng/ul methyl parathion-ethanol solution) Detection limit: ≤4×10-12g/s (P of 10ng/ul methyl parathion-ethanol solution) Dynamic range: ≥S 103 Dynamic range: ≥P 104 Temperature 350ºC |
|
Injection Method | Various injection methods are available: 1.Packed column injection; 2.Packed column gasification injection; 3.Capillary split/splitless injection: back pressure valve control technology, linear split; 4.Six-way valve gas injection; 5.On-line injection: continuous injection for 24 hours without supervision |
|
Power Supply | AC220V±10%, 50/60Hz | |
Standard Accessory | FID detector, Chromatography workstation software, Capillary sampler | |
Optional Accessory | Sample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converter | |
Sizes(W×D×H)(mm) | 530x505x510mm | |
Shipping Size(W×D×H)(mm) | 800x750x750 | |
N.W./G.W. (kg) | 42/68 |