With a stroke control accuracy of less than 0.5%, the syringe pump ensures accurate and reliable fluid delivery in the perfusion mode.
The syringe pump offers a wide range of flow rate adjustments to meet a variety of experimental requirements.
A calibration programme allows the pump to achieve more precise levels, improving the accuracy and repeatability of experiments.
With a rated linear thrust of over 290N, the pump provides sufficient force for consistent and reliable fluid transfer.
The syringe pump is equipped with multiple control inputs, including start and stop control, trigger signal control and TTL level signal control, providing versatility in operation
External control interface supports input/output control functions.
Achieve precise flow rates with liquid volume calibration function.
Prevent syringe damage with the syringe protection function, adjustable via a limit block
The syringe pump is suitable for biological laboratory, electrophysiology, chemistry, pharmaceutical and many other general fields.
Model | SP-21C |
---|---|
Working Mode | Working mode (perfusion) |
Execution Unit Quantity | 1 |
Stroke Resolution | 0.156 um |
Linear Velocity Range | 5μm/min-130 mm/min (Flow rate = linear velocity x internal cross-sectional area of syringe) |
Stroke Control Accuracy | The error≤0.5% (Trip≥30% of the maximum trip) |
Flow Correction | More accurate fluid levels are obtained through calibration procedures |
Syringe Selection | Built-in main manufacturer, model syringe for choice |
Applicable Power Supply | Broad voltage AC 90-265V.50 Hz/60 Hz |
Working Environment | Temperature 0~40°C, relative humidity <80% |
Drive Weight | 3.9 Kg |
Communication Interface | RS 485(MODBUS Protocol) |
Power Consumption | <15W |
Control Type Input | 2 start and stop control inputs, 1 falling edge trigger signal control start and stop; 1 tTL level signal control start and stop |
Maximum Stroke | 140 mm |
Status Output | 2OCgate signal output, used to indicate the start, stop and direction status |
Rated Linear Thrust | >290N |
Display Parameter Setting | Fluid volume, flow rate, or linear velocity |
Linear Speed Adjustment Resolution | 5μm/min |
Operation Parameter Setting | Dispense fluid volume, syringe time, etc |
External Size (LxWxH)(mm) | 280x210x140 |
Syringe Customization | Can be directly input into the syringe |
Applicable syringe (or injector) specifications | Applicable syringe diameter (mm) | Reference flow range (ul/ min-ML /min) |
---|---|---|
10μl | 0.50 | 0.001-0.0255 |
25μl | 0.80 | 0.0025-0.0653 |
50μl | 1.10 | 0.0048-0.1235 |
100μl | 1.60 | 0.0101-0.2614 |
250μl | 2.30 | 0.0208-0.5401 |
500μl | 3.25 | 0.0415-1.0784 |
1ml | 4.72 | 0.0875-2.2747 |
2ml | 9.00 | 0.3181-8.2702 |
5ml | 13.10 | 0.6739-17.522 |
10ml | 16.60 | 1.0821-28.135 |
20ml | 19.00 | 1.4176-36.859 |
30ml | 23.00 | 2.0774-54.012 |
60ml | 29.14 | 3.3346-86.699 |