SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

Product Details
Customization: Available
After-sales Service: 24-hour online service,free accessories
Sample Type: normal
Still deciding? Get samples of US$ 65/unit
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (21)
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
  • SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
BCC-2
Environment
Normal Pressure and Temperature
Display
Digital Display
Performance
Semi-automatic
Power Supply
220/110V,50/60Hz
Weight
0-50kg
Certification
CE, ISO 9001/14001/45001
Customized
Customized
Counter Capacity
0-999
Magnification
3 times (or 9 times)
Counting Method
Pressure sensitive
N.W./G.W. (kg)
7.3/15
Shipping Quantity
4
Consumption Rating of Lamp
16W
Transport Package
Standard Export Package
Specification
BCC-2
Trademark
SCITEK
Origin
China
HS Code
90291090
Production Capacity
100 Units/Months

Packaging & Delivery

Package Size
60.00cm * 37.00cm * 45.00cm
Package Gross Weight
15.000kg

Product Description

Product Description

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

Bacterial Colony Counter Feature:

BCC-2 is consists of counter, sensor,counting cell etc, reasonable design which can give a visible colony comparing, easy to observe, couple with special pen, it will be ring when count and ensure the accuracy of the testing, apply to Petri dish from φ50-φ100mm, the magnification is variable, It is a necessary instrument for all levels of health and epidemic prevention stations.

  1. Energy-saving round fluorescent lamps for side illumination and sharp colony contrast.

  2. High degree of automation reduces the need for manpower and improves work efficiency.

  3. Clear colony counter scale, easy to read at a glance

  4. Adopts easy-to-clean material; just wipe it with a wet towel

  5. Suitable for use in hospitals, biopharmaceuticals, clinics, university research centers and other areas.

  6. Equipped with a counting pen probe, it can accurately count each colony to avoid errors.

  7. 9X magnification makes the colonies visible and the details more clearly defined.

 

 

Semi-automatic bacterial colony counter applications:

Semi-automatic bacterial colony counters are tools used in microbiological laboratories to assist in the counting of bacterial colonies on agar plates. These devices help in automating the counting process and reduce the risk of human error. Some of the common applications and steps in using semi-automatic bacterial colony counters are as follows.

  1. Preparation of agar plates: Before using a colony counter, you need to prepare agar plates with bacterial samples. A known dilution of the bacterial solution is applied to the surface of the agar and the colonies are allowed to grow.

  2. Capture the image: Place the agar plate containing the colonies under a suitable light source. Capture an image of the agar plate in a colony counter using a camera or integrated camera system. Ensure proper lighting for optimal image quality.

  3. Transferring images to software: Transfer the captured images to the software associated with the semi-automatic colony counter. This software is used to analyse the images and assist in the counting of bacterial colonies.

  4. Image Analysis: The software will analyse the image and identify individual bacterial colonies. It can use algorithms to distinguish between colonies and background based on factors such as size, shape and colour.

  5. Adjustment of parameters: Some colony counters allow the user to adjust analysis parameters to optimise the accuracy of colony detection. This may include setting minimum and maximum size thresholds or adjusting sensitivity.

  6. Reviewing and confirming results: After the initial analysis, the software usually provides a preliminary count of bacterial colonies. Review the results and manually confirm or adjust the count if necessary.

  7. Export data: After the counting process is complete and validated, export the data. This may include colony counts, size and other relevant information.

  8. Interpret data: Analyse the collected data for further insights. This may involve calculating colony forming units (cfu) per unit volume or evaluating the efficiency of an antimicrobial treatment.

By using semi-automatic bacterial colony counters, laboratories can increase efficiency, reduce the time required for colony counting and improve the accuracy of microbiological analyses.

Product Parameters

 

Bacterial Colony Counter Specifications:

Model BCC-2
Counting Range 0~999
Diameter of the Counting Plate φ115mm
Magnification 3 times (or 9 times)
Power Supply AC100~240V, 50/60Hz
Consumption Rating of Lamp 16W
Total Consumption 20W
Shipping Quantity 4
Shipping Size(W×D×H)(mm) 600x370x450
N.W./G.W. (kg) 7.3/15
 

Company Profile


SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

Our Advantages

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

Certifications

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

Packaging & Shipping

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

FAQ

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

SCITEK Semi-automatic Bacterial Colony Counter By Image Analysis

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More