Full titanium burner, stable combustion and fast heat balance.
Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument
Comprehensive and safe smart gas control module.
Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click
Novelly designed atomizer and intelligent lifting.
Model | SP-AA3604F | SP-AA3608F | |
Optical System | Optical System | Single Beam | |
Monochromator | Czerny-Turner type, focal lengths at 350mm | ||
Grating | Grating 1800 lines/mm, scintillation wavelength 250nm | ||
Spectral Bandwidth (nm) | 0.1, 0.2, 0.4, 0.7, 1.4, 2nm Automated slit selection | ||
Wavelength Range (nm) | 185-900nm | ||
Wavelength Accuracy(nm) | 0.3 nm | 0.2nm | |
Wavelength Repeatability (nm) | ≤0.1nm | ||
Spectral Bandwidth Deviation | ±0.02 nm | ||
Lamp Stand | 4 | 8 | |
Element Lamp Type | Cu lamp(Standard accessory) | ||
Other element lamp is optional accessory | |||
Photometric Performance | Reading Mode | Transmittance, absorbance, concentration | |
Photometric Range | 0-125%,-0.1-3.00A | ||
Static Baseline Drift (Cu) | ±0.004A/30min | ±0.003A/30min | |
Dynamic Baseline Drift (Cu) | ±0.006A/15min | ±0.005A/15min | |
Flame System | Characteristic Concentration (Cu) | ≤0.04ug/ml | ≤0.035ug/ml |
Detection Limit (Cu) | ≤0.008ug/ml | ≤0.006ug/ml | |
Repeatability (Cu) | RSD≤1% | RSD≤0.6% | |
Acetylene Flow Control | Auto 12-Level | ||
Air Assist Control | Auto 4-Level | ||
Burner lift | Automatic lifting | ||
Burner Head | Titanium 100mm burner | ||
Nebulizer | High efficiency glass nebulizer | ||
Spray Chamber | Corrosion-resistant material spray chamber | ||
Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched | ||
Data Processing | Measuring Method | Flame method, Hydride generation-Atomic absorption method, Flame emission method | |
Concentration Calculation Method | Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method | ||
Repeat Measurement Times | 1-30 times. Calculate and give the average value of absorbance/concentration. standard deviation and relative standard deviation | ||
Report Printing | Parameter printing, Data result printing | ||
Other | Computer | External connect | |
Ambient Temp | 10ºC-30ºC | ||
Ambient Humidity | 40%-85% | ||
Power Supply | 220/110V, 50/60HZ | ||
External Size (WxDxH)(mm) | 830x650x560 | ||
Shipping Size (WxDxH)(mm) | 1000x780x810 | ||
N.W./G.W. (kg) | 90/110 | ||
Standard Accessory | Software, Air compressor, Cu Hollow cathode lamp | ||
Optional Accessory | Computer, Printer, Hydride generator, Autosampler |